Programming the essentials radiator thermostat MATRIX Basic

February 6, 2025
Programmierung des essentials Heizkörperthermostat MATRIX Basic
Published on  Updated on  
View products compatible with this guide

These devices do not have a wireless connection and must be set manually on the device.


For parts of this guide there is a YouTube tutorial:


1. Set the date and time (“dAt”)

After inserting the batteries, the device automatically enters installation mode . The display shows "InS" for 2 seconds .

  1. Use the dial to set the date and time:

    • Year: (2001–2099)
    • Month: (1–12)
    • Day: (1–31)
    • Hours: (0–23)
    • Minutes: (0–59)
  2. Save each entry with the confirmation button to move to the next setting.

  3. If the device does not automatically enter installation mode, briefly remove the batteries and then reinsert them .

💡 Note: The date can be adjusted again later via the menu.


2. Set the weekly program (“PRO” mode)

The thermostat allows for individual time control , so that different temperatures can be set for different times of the day.

Start programming:

  1. Press and hold the mode button (“G”) until “PRO” appears on the display.
  2. Select days:
    • Individual days
    • Working days (Mon–Fri)
    • Weekend (Sat–Sun)
    • All week (Mon–Sun)
    • → Select with the rotary wheel and confirm with the confirmation button.

Define heating times:

  1. Select start time (in 15-minute increments)
  2. Set target temperature for this phase
  3. Select end time of phase
  4. Define next heating phase
    • Up to 9 heating phases per day possible
    • After 7 set times, the programming is automatically completed
    • Alternatively, the entry can be ended with an end time of 24:00

Factory settings of the weekly program:

  • 00:00–06:00 → 17°C
  • 06:00–09:00 → 21°C
  • 9:00–17:00 → 17°C
  • 5:00 PM–11:00 PM → 21°C
  • 11:00 PM–12:00 AM → 17°C

💡 Note: Changes are only valid until the next programmed switching time.


3. Change operating modes

The thermostat offers three different operating modes: Automatic, Manual and Holiday Mode .
These can be switched by briefly pressing the mode button “G” .

  • Automatic mode (no light on B & D)

    • Device follows a programmed schedule.
    • Temperature can be temporarily changed using the rotary dial.
  • Manual mode (D lights up)

    • A fixed temperature remains permanently set.
  • Vacation mode (B lights up)

    • Temperature remains constant over a specified period of time.
    • Set start and end dates.

4. Set comfort and energy saving mode

The thermostat offers two preset temperatures:

  • Comfort temperature: factory setting 21°C
  • Energy saving mode: factory setting 17°C

Change of values:

  1. Press and hold the Energy Saving/Comfort Mode button (“E”).
  2. Turn the dial to set the desired temperature.
  3. Press the confirmation button to save the value.

💡 Note: These modes are available in both automatic and manual mode .


5. Automatically change daylight saving time (“dst”)

  1. Open the menu: Press and hold the mode button “G” until “dst” appears.
  2. Use the rotary wheel to select “ON” (active) or “OFF” (deactivated).
  3. Press the confirmation button.

6. Window-open detection (“Aer”)

If the thermostat detects that the room temperature suddenly drops by 5°C within 5 minutes , this is interpreted as an open window .

  • Standard temperature during open window: 15°C
  • Standard duration: 10 minutes

Adjust settings:

  1. Open menu (long press “G” until “Aer” appears).
  2. Use the rotary dial to set the temperature (0.5°C–29.5°C) and duration (0–60 minutes).
  3. Press the confirmation button.

💡 Note: If the duration is set to 0, the function is deactivated.


7. Offset temperature (“tOF”)

Since the thermostat measures the temperature directly on the radiator , deviations from the room temperature may occur.

  • To compensate for this, an offset of ±5.5°C can be set.

To set the offset:

  1. Open menu (press and hold “G” until “tOF” appears).
  2. Use the rotary knob to set the desired offset value (-5.5°C to +5.5°C).
  3. Press the confirmation button.

💡 Example: If 18°C ​​is reached in the room instead of the desired 20°C , an offset of +2.0°C can be set.


8. Restore factory settings (“rES”)

If you want to reset the thermostat to factory settings :

  1. Open menu (long press “G” until “rES” appears).
  2. Press the confirmation button → “COnF” is displayed.
  3. Press the confirmation button again.

⚠️ Attention: All individual settings will be lost!


Summary

The essentials MATRIX radiator thermostat (SKU: 120195) is programmed entirely manually via the device . In addition to individual weekly programming , comfort and economy modes, open window detection, a temperature offset, and automatic daylight saving time adjustment can also be configured.

Published on  Updated on