SPECIFICATIONS
PHYSICAL
Size (HxWxD):
37x42x15 ±0.5 mm / 1.46 x 1.65 x 0.59 ±0.02 in
Weigh:
105g / 3.70oz
Shell material:
Plastic
Color:
Black
ENVIRONMENTAL
Ambient temperature:
-20°C to 40°C / -5°F to 105°F
Humidity
30% to 70% RH
Max. altitude
2000 m / 6562 ft
ELECTRICAL
Power supply voltage AC:
N/A
Power supply voltage DC:
3.3V (from Shelly plus device)
Power consumption:
< 0.5 W (without sensors)
OUTPUT CIRCUITS RATINGS
VCC max. current:
10mA
VREF OUT max. current:
1mA
SHELLY PLUS DEVICE FIRMWARE CAPABILITIES
Shelly Plus Addon supporting devices:
Shelly Plus 1/1PM, Shelly Plus 2PM, Shelly Plus i4/i4DC
Temperature reading:
Depends on the DS18B20 or DHT22 sensors
Humidity reading:
Depends on the DHT22 sensor
Digital input:
-15V to 0.5V (True) / 2.5V to 15V (False)*
Analogue input range:
0 to 100%
Analog input report threshold:
1%**
Voltmeter range:
0 to 10V
Voltmeter report threshold:
0.1V**
Analog input / voltmeter accuracy
Better that 5%